The 820 Electronics module is the right fit for the fuel measurement application and has Emerson�s Adaptive Consumption Measurement software added. This electronics module allows for two flow meters to be connected to a single source and therefore provides a 4 to 1 reduction in electronic components. This solution improves the signal processing speed between the supply and return measurement points, ensuring an accurate instantaneous consumption calculation.
Measurement Type: Compliant with MID 2014/32/UE Annex MI-002 and Annex MI-005
Temperature Range: Process fluid temperature -320 to +140 °F (-196 to +60 °C)Ambient temperature -40 to +140 °F (-40 to +60 °C)
Weight: Electrical parts 2.9 kg
Connection Type(s): – One pair of wiring terminals for RS-485 signal cable connection– One pair of wiring terminals accepts 24V DC power– Two 9-wire connections for sensors– Service port connection via two clips for temporary connection
Housing: Polyurethane-painted aluminum
Mounting: Remote mounting options