Danfoss 137U3550 Frequency Converter FC-102N400T4E5MH2TLC3XQLX1XXAQB5CXXXXD0 VLT® HVAC Drive FC-102 (N400) 400 KW / 550 HP, Three phase 380 - 480 VAC, IP54/Type 12+main shield RFI Filter Safe Stop Graphical LCP + USB Coated PCB, Mains Disconnect + Fuse Condition Based Monitoring CBM Frame: E1H No C1 option, MCB-107 24V DC backup Modbus TCP MCA 122, MCB-115 Programmable I/O 
| Gross weight |  | 295.3 kg |  | 
| Net weight |  | 295 kg |  | 
| Volume |  | 0 l |  | 
| EAN |  | 5715253719269 |  | 
VLT® HVAC DRIVE FC 100 SERIES
| Product View (Switch) | GLBL | Global (Standard) |  | 
| Product Group | FC- | VLT® HVAC Drive FC- |  | 
| Series | 102 | 102 |  | 
| Power Rating | N400 | (N400) 400 KW / 550 HP |  | 
| Phase | T | Three phase |  | 
| Mains Voltage | 4 | 380 - 480 VAC |  | 
| Enclosure | E5M | IP54/Type 12+main shield |  | 
| RFI Filter | H2 | RFI Filter |  | 
| Brake - Safe Stop | T | Safe Stop |  | 
| LCP | L | Graphical LCP + USB |  | 
| Coating PCB | C | Coated PCB |  | 
| Mains Option | 3 | Mains Disconnect + Fuse |  | 
| Adaptation A | X | Standard Cable Entries |  | 
| Adaptation B | Q | Heat-sink access |  | 
| Software Release | LX1X | Condition Based Monitoring CBM |  | 
| Software Language Pack | X | Standard Language Pack |  | 
| A Option | AQ | Modbus TCP MCA 122 |  | 
| B Option | B5 | MCB-115 Programmable I/O |  | 
| C0 Option MCO | CX | No C0 option |  | 
| C1 Option | X | No C1 option |  | 
| C Option Software | XX | No software option |  | 
| D Option | D0 | MCB-107 24V DC backup |  | 
| Frame Size | E1H | E1H |  | 
| Product Catalog | NO_VIEW | NO VIEW |  | 
| Typecode Part 1 |  | FC-102N400T4E5MH2TLC |  | 
| Typecode Part 2 |  | 3XQLX1XXAQB5CXXXXD0 |  | 
| Power 110% (NO) [KW] |  | 400 |  | 
| Height [mm] |  | 2000,0 |  | 
| Width w/ no C options [mm] |  | 600,0 |  | 
| Depth [mm] |  | 510,0 |  | 
| Depth with Option A/B [mm] |  | 510,0 |  | 
| kVA |  | 516 |  | 
| Power Loss NO [W] |  | 8036 |  | 
| Power Loss NO [W] |  | 6933 |  | 
| Continuous Current (NO) [A] |  | 745 |  | 
| Intermittent Current (NO) [A] |  | 820 |  | 
| Continuous Current (NO) [A] |  | 678 |  | 
| Intermittent Current (NO) [A] |  | 746 |  | 
| Calculated Gross Weight [kg] |  | 295.3 |  | 
| Calculated Net Weight [kg] |  | 295 |  | 
| ECCN EU |  | Y901 |  | 
| ECCN US |  | 3A999.a |  | 
| Plant from Orderline |  | F605 |  | 
| Vendor | ERR01 | Cannot Determine Vendor |  | 
| Recommended Factory | ERR01 | Cannot Determine Vendor |  | 
| Modelcode01 |  | FC-102N400T4E5MH2TLC |  | 
| Modelcode02 |  | 3XQLX1XXAQB5CXXXXD0 |  |