Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature
Certifications/Approvals: Hazardous location, see full specs for complete list of certifications
Lead Wires: 24 AWG wire, FEP insulated. Color coded per IEC 60584 or ASTM E230.
Insulation Resistance: 1000 MΩ minimum insulation resistance when measured at 500VDC at room temperature
Certifications/Approvals: Hazardous location, see full specs for complete list of certifications
Input: Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal: WirelessHART® protocol
Housing: Dual-compartment field mount
Display/Interface: Large LCD display with percent range graph
Diagnostics: Basic diagnostics including open/short sensor diagnostics
Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants)
Certifications/Approvals: Hazardous location, marine type, see full specs for complete list of certifications
Update Rate: 1 sec. to 60 min., user selectable
Power Module Life: Up to 10-year life, field replaceable (order separately)
Antenna Type: External (standard and extended range)
Thermowell Calculations: Wake frequency calculation (WFC) performed by certified engineers, order R21 for official report
Design Modifiers: Root, bore and tip diameters can be customized for any application
Certifications/Approvals: Material certification, NACE, CRN (see full specs for complete list of certifications)
Product Tests: External pressure test, internal pressure test, dye penetration, X-ray, PMI (see full specs for complete list)