The Flexim FLUXUS H721 is Flexim’s flow and analytical measuring system for the hydrocarbon processing industry (HPI). This sophisticated and highly accurate non-intrusive flow meter combines precise ultrasonic flow and sound speed measurement with advanced calculation features and diagnostics. The H721’s nonintrusive flow meter built-in HPI computer calculates API gravity, operational density, density at base conditions and kinematic viscosity. Volumetric flow rates reported by the meter are automatically compensated for temperature and pressure within the meter according to industry standards ASTM1250, GPA TP25 and D4311 thus allowing for precise and dynamic standard volume flow measurement of liquid hydrocarbons.
Fluid type: Various hydrocarbons
Accuracy: Measurement uncertainty of the measuring system (volumetric flow rate): ±0.3 % of reading ±0,005 m/s (±0.02 ft/s)Measurement uncertainty at the measuring point (volumetric flow rate): ±1 % of reading ±0,005 m/s (±0.02 ft/s)
Repeatability: 0.15 % of reading ±0,005 m/s (±0.02 ft/s)
Flow Channels: up to 2
Range: Flow Velocity Range: 0,01…25 m/s (0.03 to 82 ft/s), depending on pipe diameter
Certifications/Approvals: FM Class I /Div 2ATEX/IECEx Zone 2PESOKOSHA
Power supply: 100-230VAC24VDC12VDC
Pipe size: 6 to 6500 mm (0.24 to 255.9 inch)
Pressure range: -
Temperature range (media): -40 to +240°C (-40 to +464°F) / WI: -200 to +630°C (-328 to +1166°F)
Output: 4-20mA active/passive4-20mA HART active/passivepulse/frequency/binaryvoltage
Input: Temperature4-20mA active/passivebinaryvoltage
Communication Protocol: Modbus RTU/TCPProfibus PAFoundation Fieldbus
System configuration and installation: For more detailed Information please download the Technical Specifications