The Flexim FLUXUS G721 CA compressed air flow meter is a non-intrusive clamp-on ultrasonic technology, unique in that it can be applied to measure compressed air flow rates even at very low pressures (down to 3bar on steel lines and atmospheric pressure on plastic lines). Also, even the lowest flow rates are accurately captures revealing the slightest flow rates from the smallest leaks where there should be none. The FLUXUS G721 CA is particularly suitable for non-intrusively Measuring Quantities drawn off at individual points in the compressed air grid as well as detecting leaks within it.
Fluid type: Air, nitrogen, oxygen, helium, argon
Accuracy: Measurement uncertainty of the measuring system (volumetric flow rate): ±0.3 % of reading ±0,005 m/s (±0.02 ft/s)Measurement uncertainty at the measuring point (volumetric flow rate): ±1…2 % of reading ±0,005 m/s (±0.02 ft/s)
Repeatability: 0.15 % of reading ±0,005 m/s (±0.02 ft/s)
Flow Channels: up to 2
Range: Flow Velocity Range: 0,01…35 m/s (0.03 to 115 ft/s), depending on pipe diameter
Certifications/Approvals: FM Class I /Div 2ATEX/IECEx Zone 2PESOKOSHA
Power supply: 100-230VAC24VDC12VDC
Pipe size: 10 to 250 mm (0.39 to 9.8 inch)
Pressure range: 1barg (15 psig) to unlimited
Temperature range (media): -40 to +130°C (-40 to +266°F)
Output: 4-20mA active/passive4-20mA HART active/passivepulse/frequency/binaryvoltage
Input: Temperature4-20mA active/passivebinaryvoltage
Communication Protocol: Modbus RTU/TCPBACnet MSTP/IPProfibus PAFoundation Fieldbus
System configuration and installation: For more detailed Information please download the Technical Specifications