Get ongoing visibility of corrosion and erosion trends in real-time with unique ultrasonic sensors that continuously measure pipe thickness. The ET310 Sensor system is non-intrusive and battery-powered, allowing for quick and straightforward magnetic installation. The reliable, accurate wall thickness data delivered via aWirelessHART™ network from the ET310 system to the accompanying software can help you make better decisions regarding pipe maintenance and replacement.
Temperature Range: May be used on metal with a service temperature up to 160 °C (320 °F)
Communication Protocol: WirelessHART
Battery Life: 9 years (BP20E power module)
Certifications/Approvals: Class 1 Div 1 or Zone 0 hazardous location, see full specs for complete list of certifications
Measurement Range: Minimum wall thickness: 4mm (0.16")Maximum wall thickness: Up to 100mm (4")
Performance: Metal loss detection capability better than 10 microns (0.5 mil) in real field conditions
Measurement Frequency: Default - every 12 hours; User configurable down to every hour