Frequency converter
FC-202P355T4E5MN2TGC3XXSXXXXA0BXCXXXXD0
VLT® AQUA Drive FC-202
(P355) 355 KW / 500 HP, Three phase
380 - 480 VAC, IP54/Type 12+main shield
LHD - AAF006 filter + A2 RFI
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, Mains Disconnect + Fuse
Latest release std. SW.
Frame: E9
No C1 option, MCB-107 24V DC backup
PROFIBUS DP MCA 101, No B Option
Gross weight 676.3 kg
Net weight 676 kg
Volume 0 l
EAN 5715253149172
VLT® AQUA DRIVE FC 200 SERIES
Product View (Switch) GLBL Global (Standard)
Product Group FC- VLT® AQUA Drive FC-
Series 202 202
Power Rating P355 (P355) 355 KW / 500 HP
Phase T Three phase
Mains Voltage 4 380 - 480 VAC
Enclosure E5M IP54/Type 12+main shield
RFI Filter N2 LHD - AAF006 filter + A2 RFI
Brake - Safe Stop T Safe Stop
LCP G Graphical Loc. Cont. Panel
Coating PCB C Coated PCB
Mains Option 3 Mains Disconnect + Fuse
Adaptation A X Standard Cable Entries
Adaptation B X No adaptation
Software Release SXXX Latest release std. SW.
Software Language Pack X Standard Language Pack
A Option A0 PROFIBUS DP MCA 101
B Option BX No B Option
C0 Option MCO CX No C0 option
C1 Option X No C1 option
C Option Software XX No software option
D Option D0 MCB-107 24V DC backup
Frame Size E9 E9
Typecode Part 1 FC-202P355T4E5MN2TGC
Typecode Part 2 3XXSXXXXA0BXCXXXXD0
Product Catalog NO_VIEW NO VIEW
Power 150% (HO) [KW] 315
Power 110% (NO) [KW] 355
Height [mm] 2000,0
Width w/ no C options [mm] 1200,0
Depth [mm] 500,0
Depth with Option A/B [mm] 500,0
kVA 456
Power Loss NO [W] 15320
Power Loss NO [W] 14083
Continuous Current (NO) [A] 658
Intermittent Current (NO) [A] 724
Continuous Current (NO) [A] 590
Intermittent Current (NO) [A] 649
Continuous Current (HO) [A] 600
Intermittent Current (HO) [A] 900
Continuous Current (HO) [A] 540
Intermittent Current (HO) [A] 810
Calculated Gross Weight [kg] 676.3
Calculated Net Weight [kg] 676
ECCN EU X.A.I.003
ECCN US 3A999
Plant from Orderline E102
Vendor ERR01 Cannot Determine Vendor
Recommended Factory ERR01 Cannot Determine Vendor
Allowed Plants E104
E105
F605
E101
E102
E103 (E104) Brisbane Distribution
(E105) Perth Distribution
(F605) Loves Park SAles
(E101) Dandenong Distribution
(E102) Derrimut Distribution
(E103) Sydney Distribution
Modelcode01 FC-202P355T4E5MN2TGC
Modelcode02 3XXSXXXXA0BXCXXXXD0

Worldwide Shipping
Tailored Quotation
Secure Shopping
24/7 Customer Support
Icon Hot
Icon Hot